Aqua RO Plant 2000 LPH Price in Pakistan
The Aqua RO Plant 2000 LPH is designed for commercial and industrial water purification applications where a high volume of treated water is required. This system uses reverse osmosis (RO) membrane technology to reduce dissolved salts, total dissolved solids (TDS), and other impurities from incoming water.
With a nominal production capacity of 2,000 litres per hour, the plant can produce approximately 16,000 litres during eight hours of operation, subject to the specified operating conditions.
The system can be configured according to feed water analysis, required product-water quality, daily demand, and available installation space.
Key Features and Benefits
- High production capacity: Nominal output of 2,000 litres per hour.
- Reverse osmosis technology: Helps reduce dissolved salts and TDS.
- Commercial and industrial applications: Designed for facilities with substantial water requirements.
- Custom pretreatment: Filtration stages selected according to raw water quality.
- Membrane protection: Suitable pretreatment helps reduce fouling and scaling.
- Performance monitoring: Pressure gauges and flow meters can be included.
- Flexible controls: Manual, semi-automatic, or automatic configurations, as specified.
- Optional water storage: Storage tanks can be included according to demand.
- Optional post-treatment: UV disinfection and other treatment stages can be added when required.
- Service and maintenance: Routine inspection helps support consistent performance.
Technical Specifications
| Specification | Details |
|---|---|
| Product Name | Aqua RO Plant 2000 LPH |
| System Type | Commercial Reverse Osmosis Plant |
| Nominal Capacity | 2,000 Litres Per Hour |
| Equivalent Capacity | 2 Cubic Metres Per Hour |
| Theoretical Daily Output | 16,000 litres in 8 hours |
| Technology | Reverse Osmosis |
| Feed Water Source | Bore water, municipal water, or another assessed source |
| Pretreatment | Selected according to water analysis |
| RO Membranes | According to final system design |
| High-Pressure Pump | Sized according to feed water and membrane requirements |
| Control Panel | As specified in the selected configuration |
| Flow Meters | According to configuration |
| Pressure Gauges | According to configuration |
| Water Storage Tank | Optional or package-dependent |
| UV Disinfection | Optional, where required |
| Installation | Subject to quotation and site requirements |
| Warranty | Confirmed in the final quotation |
| Price in Pakistan | Contact for current price |
The exact membrane quantity, pump power, operating pressure, recovery rate, electricity consumption, dimensions, construction materials, and included accessories must be confirmed for the actual unit supplied.
Daily Production Capacity
Aqua RO Plant 2000 LPH has a nominal output of 2,000 litres per hour under its specified operating conditions.
- 8 operating hours: approximately 16,000 litres
- 10 operating hours: approximately 20,000 litres
- 16 operating hours: approximately 32,000 litres
- 20 operating hours: approximately 40,000 litres
- 24 operating hours: approximately 48,000 litres
These figures are theoretical calculations based on the rated hourly output. Actual production may vary because of feed water quality, temperature, operating pressure, membrane condition, maintenance, and downtime.
Applications of Aqua RO Plant 2000 LPH
This commercial RO plant can be considered for:
- Commercial water purification businesses
- Water filling and distribution facilities
- Factories and manufacturing units
- Hotels and hospitality facilities
- Schools, colleges, and universities
- Hospitals and large commercial buildings
- Food and beverage processing
- Housing societies and community facilities
- Other industrial applications requiring treated water
The appropriate configuration depends on the final water-quality requirements and intended use.
How Does Aqua RO Plant 2000 LPH Work?
1. Raw Water Supply
Incoming water enters the system from the selected source.
2. Pretreatment Filtration
Suitable filtration stages remove suspended particles and other substances that may affect RO membrane performance. Water softening or chemical dosing may be required depending on the water analysis.
3. High-Pressure Pumping
The pump supplies the pressure needed for the reverse osmosis process.
4. RO Membrane Filtration
The membranes separate treated water from concentrated reject water and reduce dissolved salts.
5. Product Water Collection
The treated water is directed to a suitable storage tank or distribution system.
6. Final Water Quality Testing
The treated water should be tested to confirm suitability for the intended application.
Aqua RO Plant 2000 LPH Price in Pakistan
The price of an Aqua RO Plant 2000 LPH in Pakistan depends on the system configuration, raw water conditions, and installation requirements.
Factors that affect the final price include:
- Raw water TDS, hardness, iron, and turbidity
- Pretreatment filters and filtration media
- RO membrane quantity and specifications
- High-pressure pump capacity
- Manual or automatic controls
- Water softener and chemical dosing equipment
- Storage tank capacity and construction material
- UV disinfection or other post-treatment
- Installation, transportation, and commissioning
- Warranty and after-sales service
For an accurate quotation, share your raw water TDS, water source, required operating hours, intended application, and installation city with Aqua Water Filter.
Maintenance and Operating Requirements
Regular maintenance is important for reliable plant operation and consistent water quality.
Recommended activities include:
- Monitoring feed water and treated water TDS.
- Checking pressure, flow rate, and system performance.
- Replacing sediment and cartridge filters when required.
- Servicing pretreatment equipment.
- Monitoring membrane performance and cleaning when indicated.
- Inspecting pumps, valves, connections, and pipelines.
- Testing treated water at appropriate intervals.
Maintenance requirements depend on the raw water quality, operating hours, and system design.
Frequently Asked Questions
What is the Aqua RO Plant 2000 LPH price in Pakistan?
The price depends on the pretreatment system, membrane configuration, pump, automation, storage, and installation. Contact Aqua Water Filter for a quotation.
What does 2000 LPH mean?
LPH means litres per hour. A 2000 LPH RO plant has a nominal production capacity of 2,000 litres of treated water per hour under specified operating conditions.
How much water can a 2000 LPH RO plant produce per day?
At its nominal capacity, it can produce approximately 16,000 litres in eight hours or 40,000 litres in 20 hours. Actual output depends on operating conditions and downtime.
Can the Aqua RO Plant reduce high TDS?
Reverse osmosis can substantially reduce dissolved salts and TDS. The actual reduction depends on the incoming water composition, membrane selection, pressure, temperature, and system condition.
Is a water softener necessary?
A softener may be required when feed water hardness creates a scaling risk. The correct pretreatment should be selected after analysing the incoming water.
Does the plant include a storage tank?
Storage tank inclusion depends on the selected package. Confirm the tank capacity and accessories in the quotation.
Is this plant suitable for a commercial drinking-water business?
It can form part of a commercial drinking-water treatment setup. Appropriate post-treatment, hygienic storage, disinfection, and water-quality testing are also necessary.
How can I get a quotation?
Contact Aqua Water Filter with your water analysis, required capacity, intended application, and installation location to discuss a suitable system configuration.
Request a Quotation Today
Looking for an Aqua RO Plant 2000 LPH in Pakistan? Contact Aqua Water Filter to discuss your commercial water purification requirements and request a quotation.





Reviews
There are no reviews yet.