1500 GPD Commercial RO Plant Price in Pakistan

+ Free Shipping

The 1500 GPD Commercial RO Plant is a reverse osmosis water purification system designed for commercial businesses and facilities requiring a dependable supply of purified water. With a nominal capacity of approximately 5,678 litres per day, this system is suitable for offices, restaurants, schools, small commercial water businesses, and selected industrial applications.

The plant can be configured with pretreatment filters, a high-pressure pump, RO membranes, monitoring instruments, and optional storage or post-treatment equipment according to the raw water quality and application requirements.

Looking for the 1500 GPD Commercial RO Plant price in Pakistan? Contact Aqua Water Filter for a quotation based on your required configuration.

Guaranteed Safe Checkout

1500 GPD Commercial RO Plant Price in Pakistan

The 1500 GPD Commercial RO Plant is designed to provide purified water for businesses and facilities that require a consistent daily water supply. It uses reverse osmosis technology to reduce dissolved salts, total dissolved solids (TDS), and various impurities from feed water.

With a nominal production capacity of 1,500 US gallons per day, equivalent to approximately 5,678 litres per day, this commercial RO system can support a range of water purification requirements.

The system configuration should be selected according to raw water analysis, desired treated-water quality, daily demand, and operating hours.

Key Features

  • Nominal capacity of 1500 gallons per day.
  • Reverse osmosis membrane filtration.
  • Reduction of dissolved salts and TDS.
  • Pretreatment options based on incoming water quality.
  • Suitable pump and membrane configuration for the design conditions.
  • Pressure gauges and flow monitoring, depending on configuration.
  • Optional water storage tank.
  • Optional automatic controls and flushing functions.
  • Optional UV disinfection and other post-treatment stages.
  • Maintenance and servicing according to operating conditions.

Technical Specifications

Specification Details
Product 1500 GPD Commercial RO Plant
Treatment technology Reverse Osmosis
Rated capacity 1,500 US gallons per day
Approximate daily output 5,678 litres
Average hourly output over 24 hours 236.6 litres
Feed water source Bore water, municipal water, or another assessed source
Pretreatment Selected according to water analysis
RO membranes As specified in the final system design
High-pressure pump Selected according to design requirements
Control panel Based on selected configuration
Storage tank Optional or package-dependent
UV disinfection Optional, if required
Installation To be confirmed with quotation
Warranty Confirmed with the supplier
Price Contact for current price in Pakistan

Actual output depends on feed water quality, temperature, pressure, membrane condition, recovery rate, and operating time. The specifications of the actual unit supplied should be confirmed before purchase.

Applications

The 1500 GPD Commercial RO Plant may be suitable for:

  • Restaurants and cafés
  • Offices and commercial buildings
  • Schools and educational institutions
  • Small commercial water supply businesses
  • Hotels and hospitality facilities
  • Food preparation and selected processing applications
  • Workshops and selected industrial uses
  • Other facilities requiring treated water

For drinking water applications, appropriate disinfection, hygienic storage, and final water quality testing are important.

How the RO Plant Works

Stage 1: Feed water intake
Raw water enters the treatment system.

Stage 2: Pretreatment
Appropriate filters help remove suspended particles and other substances that may damage or foul the RO membranes.

Stage 3: High-pressure pumping
The pump supplies the pressure required for the reverse osmosis process.

Stage 4: Membrane filtration
The RO membranes separate purified water from concentrated reject water, reducing dissolved salts.

Stage 5: Water collection
The treated water is directed to a suitable storage tank or distribution system.

Stage 6: Quality testing
The finished water should be tested to ensure it is suitable for its intended application.

1500 GPD Commercial RO Plant Price in Pakistan

The price of a 1500 GPD Commercial RO Plant depends on its equipment, design, and installation requirements.

Factors affecting the final price include:

  • Raw water TDS and hardness
  • Suspended solids, iron, and other contaminants
  • Pretreatment filter size and media
  • RO membrane quantity and specifications
  • Pump capacity and electrical requirements
  • Manual or automatic operation
  • Storage tank and distribution equipment
  • UV disinfection or other post-treatment
  • Installation, transportation, and commissioning
  • Warranty and maintenance arrangements

For a suitable quotation, provide your raw water TDS, water source, required daily output, intended use, and installation city.

Maintenance Requirements

Regular maintenance helps support reliable operation and consistent water quality.

Recommended maintenance activities include:

  • Monitoring feed water and treated water TDS.
  • Checking operating pressure and water flow.
  • Replacing pretreatment cartridges when required.
  • Maintaining carbon and other pretreatment media.
  • Monitoring membrane performance and cleaning when indicated.
  • Checking pumps, valves, electrical connections, and leakage.
  • Testing the final water quality at suitable intervals.

Maintenance frequency depends on raw water quality, operating hours, and system design.

Frequently Asked Questions

What is a 1500 GPD RO Plant?

It is a reverse osmosis system with a nominal rated capacity of 1,500 US gallons per day, equivalent to approximately 5,678 litres per day.

What is the 1500 GPD Commercial RO Plant price in Pakistan?

The price varies according to pretreatment, pump and membrane selection, automation, storage, and installation. Contact Aqua Water Filter for a quotation.

How many litres does a 1500 GPD RO Plant produce per hour?

The nominal average is approximately 237 litres per hour when the daily capacity is spread over 24 operating hours. Actual production may differ.

Can this RO Plant reduce high TDS?

Reverse osmosis can substantially reduce dissolved salts. The actual reduction depends on feed water composition, membrane selection, operating conditions, and maintenance.

Is a storage tank included?

Storage is configuration-dependent. Confirm whether a tank is included and specify the required storage capacity when requesting a quotation.

Does the plant require pretreatment?

Pretreatment is commonly necessary to protect the membranes. The appropriate filters and treatment stages should be selected after analysing the feed water.

Can this system be used for drinking water?

It may form part of a drinking-water treatment system, but the complete installation must include suitable treatment, hygienic storage, and testing against applicable drinking-water requirements.

Request a Quotation from Aqua Water Filter

For details about the 1500 GPD Commercial RO Plant, contact Aqua Water Filter with your water analysis and installation requirements.

Reviews

There are no reviews yet.

Be the first to review “1500 GPD Commercial RO Plant Price in Pakistan”

Your email address will not be published. Required fields are marked *